Roland Heater Error: TEMPERATURE IS TOO LOW, Heater Not Heating and What to Check
Your Roland shows TEMPERATURE IS TOO LOW, takes forever to warm up, or one heater simply won't heat? From the service bench, I explain how to separate room conditions, settings and a real heating fault, and what you can safely check before you order a single part.
The mistake I see most with a Roland heater error is ordering a new heater before anyone checks the room. The printer shows TEMPERATURE IS TOO LOW, sits there "warming up" forever, or prints with one zone that won't heat and leaves the ink wet on one side, and the conclusion is instant: something burned out.
Plenty of printers come to my bench with this warning, and a good share of them had nothing broken: the cause was the room, the settings or the power. This page covers the error and fault side of heating on the SP-540V, VP-540/540i, VS-640/640i, RS-640, RE-640 and RF-640. If the heaters work and the ink just won't dry, read the article on Roland ink not drying instead. Diagnosing a cold zone is something I show on video in the course.
Sound familiar?
- TEMPERATURE IS TOO LOW on the display first thing in the morning.
- The printer takes forever to be ready.
- One heater zone never reaches temperature.
- Ink comes out wet in just one strip of the media.
- The temperature on the panel keeps climbing and dropping.
How Roland heating works
Roland eco-solvent printers use heaters along the media path: the print heater, under the area where ink lands, the dryer at the exit and, on some models, a pre-heater at the entry. Each zone has a temperature sensor reporting to the board, and the board switches the heater on and off to hold the set value.
When the machine can't reach or hold the expected temperature, it waits, warns or blocks printing. The warning doesn't tell you the cause, only that temperature is out of the expected range.
What TEMPERATURE IS TOO LOW usually points to
Treat this message as a temperature-related warning, not a diagnosis. Depending on the model, it can relate to the room being below the operating range, to heaters that haven't reached the set temperature yet, or to both at once. It doesn't point to a single cause. That's why, before thinking about parts, I always start with the most common culprits: a cold room, a draft, or a printer that was just switched on.
The red flag is when the message appears with the room at normal temperature, after the printer has been on for a good while, or always in the same heater zone.
Most common causes of a temperature error
1. Cold room and drafts
An AC unit blowing straight onto the platen, an open door, a cold warehouse early in the morning. The heater works, but it loses heat faster than it can produce it.
A typical shop case: a printer threw a temperature warning every morning, and the owner had already ordered a new heater. On site, the AC vent was aimed right at the platen and the warehouse door stayed open until mid-morning. Redirect the airflow, give the printer time to warm up before the first job, and the warning was gone, no part needed.
2. Settings
A set temperature too high for the environment, a heater switched off in the media settings, or values that differ between the panel and the RIP. In practice, a lot of the "heater failures" I get called about are just settings.
3. Warm-up time and sleep mode
After power-on or waking from sleep, the heaters need time. Sending a print before that leads to waiting and warnings.
4. Power
Low or unstable voltage reduces heating capacity. An undersized regulator and a circuit shared with other heavy equipment show up a lot here.
5. Faulty temperature sensor, heater or connection
A zone that never heats, swings wildly or shows an absurd temperature points to the sensor, heating element, connector or control. It's the minority of cases, but it's where improvising gets dangerous.
Symptoms that help separate the causes
- Slow only in the morning or in winter: environment.
- One specific zone never reaches temperature: that zone's sensor, heater or connection.
- Temperature rises and drops nonstop: draft, power or unstable reading.
- Panel shows temperature, but media comes out wet in one band only: a problem zone or media not sitting flat.
- Error appeared after a move or electrical change: power and installation.
A heater that won't heat means a dead morning or a banner coming back because the ink never set.
Separating room, settings, power and a real fault, zone by zone, without putting your hands where they don't belong, is exactly the diagnosis I show on video inside Manual de Campo, on a real machine. Fix my Roland's heating the right way →
Basic, safe checks
The platen and heaters get hot enough to burn you. Don't touch them to "feel" the temperature. For any inspection, power down from the panel, switch off the main power, unplug it and let it cool. Never open electronics covers or handle heater connectors.
1. Environment
- check the room temperature and whether an AC unit, fan or door is blowing over the printer;
- leave the printer on for a while before the first job of the day.
2. Settings
- check on the panel that the heaters are on and set to realistic values;
- make sure the media settings in the RIP aren't switching off or changing the heating;
- test with a known setting that has always worked.
3. Power
- a firm outlet, a cord in good condition, no power strips;
- a regulator or UPS rated for the printer with heaters running;
- wiring and grounding evaluated by a qualified electrician.
4. Observe and record
- which zone fails, how long the printer takes to be ready and at what time of day;
- if nothing changes with a warmer room, correct settings and good power, you've moved past the basics.
How far to go on your own, and where Manual de Campo comes in
Environment, settings and power are within your reach and explain most temperature errors. When they don't, the diagnosis moves into:
- confirming whether that zone's temperature reading can be trusted;
- separating sensor, heater, connection and control;
- deciding with real criteria between adjustment, repair or replacement;
- building a per-media heating and drying routine that prevents the problem.
This is where heat and electricity meet, and one careless move costs you a burn or a board. That's why I show the diagnostic logic on video, on a real machine, inside Manual de Campo, making clear what is safe to do and what is a job for a qualified technician. Alongside that, a solid Roland maintenance checklist prevents a lot of downtime.
If you've already checked the room, the settings and the power and your Roland still reports low temperature or has a cold zone, stop swapping parts in the dark. Join Manual de Campo, follow the heating diagnosis on video and get back to printing on schedule, with ink that dries the way it should.
Quick questions about Roland heater and temperature errors
Frequently Asked Questions
1. What does TEMPERATURE IS TOO LOW mean on a Roland?
It warns that temperature is below what the printer needs to work. Depending on the model, it can relate to the room, to heaters that haven't reached temperature yet, or to both, and the message alone doesn't tell you which. Start by checking the room, any drafts and how long the printer has had to warm up.
2. Why does my Roland take so long to warm up?
A cold room, a draft over the platen, a set temperature that's too high and weak power are the most common causes. If the delay is always in a single zone, then it's worth suspecting that area's sensor or heater.
3. One of the heaters won't heat. What could it be?
First check it's switched on in the panel and media settings. If everything is correct and the zone stays cold, it may be the sensor, heating element or a connection, and that diagnosis should be done methodically or by a qualified technician.
4. Can I touch the platen to see if it's hot?
No. The heaters can burn your skin. Watch how the ink behaves and the values on the panel, and do any inspection only with the printer off, unplugged and cool.
5. When does the Manual de Campo protocol make sense?
When environment, settings and power have been checked and the error persists, or when a specific zone doesn't respond. I show that diagnosis on video, on a real machine, inside Manual de Campo.